ODSENSE
English
EnglishEspañol — Borrador para revisión · Sin publicarPortuguês do Brasil — Rascunho para revisão · Não publicadoالعربية — مسودة للمراجعة · غير منشورةBahasa Indonesia — Draf untuk ditinjau · Belum diterbitkanFrançais — Brouillon à relire · Non publiéDeutsch — Entwurf zur Prüfung · Nicht veröffentlichtРусский — Черновик для проверки · Не опубликованTiếng Việt — Bản thảo để duyệt · Chưa xuất bảnไทย — ฉบับร่างสำหรับตรวจสอบ · ยังไม่เผยแพร่
ODSENSE · Technical insights

Temperature Sensor Radiation Shield: Check Sun and Airflow Bias

Temperature Sensor Radiation Shield: Check Sun and Airflow Bias

A temperature sensor radiation shield reduces heating from direct sun while allowing ambient air to pass around the probe. If one outdoor sensor reads higher during sunny, calm periods, examine the shield and mounting before changing the probe calibration. Compare both sensors during shaded or windy periods as a second check.

Recognize a shortwave radiation pattern

Compare the temperature difference with solar irradiance and wind speed. An error that grows in strong sun when airflow falls is consistent with radiative heating, but local surfaces or mounting can produce a similar pattern. Campbell Scientific's station design guide explains the use of naturally ventilated and fan-aspirated shields.

Inspect the fit and surrounding surfaces

Verify the probe position inside the shield, the condition of the plates, and the free space around the openings. Check for dirt, obstruction, and warm surfaces such as walls, roofs, or exhausts. Compare at representative locations and the same measurement height. The agricultural temperature sensor placement guide explains why nearby surfaces matter.

A radiation shield blocks direct sunlight while allowing ambient air to flow past the temperature probe.
A radiation shield blocks direct sunlight while allowing ambient air to flow past the temperature probe.

Test passive and aspirated shields under comparable conditions

Place a suitable reference probe near the test shield at the same height and over comparable ground. Log both instruments through sunny, calm weather and a lower-radiation period. For an aspirated reference, confirm that the fan runs and the flow path is clear. Campbell Scientific's EE181 manual shows installation geometry for specific probe and shield combinations.

Check whether the enclosure is slowing the response

Compare the traces around a sustained temperature change and distinguish delay from a persistent offset. A change limited to sunny hours suggests checking heat transfer before changing a constant offset. The humidity sensor response-time guide describes a similar method for separating probe response from installation lag. Record wind exposure using the wind sensor siting guide when interpreting calm periods.

Frequently asked questions

Should I choose a fan-aspirated shield for every site?

Choose based on the required uncertainty, expected sun and wind, and ability to maintain power and airflow. Verify the installation under the conditions that matter to the project.

Discuss your project

Send your project enquiry to linda@odsenses.com. Required fields are marked with an asterisk.