YF500-WQ · Multi-parameter water quality sensor

The YF500-WQ measures water pH, conductivity and temperature. Dissolved oxygen and other channels are optional; confirm the probe combination and conductivity cell constant.

Measurement parameters

YF500-WQ · Multi-parameter water quality sensor

Product photograph · YF500-WQ

Source reviewed · Configuration to confirm

YF500-WQ · Multi-parameter water quality sensor

The YF500-WQ measures water pH, conductivity and temperature. Dissolved oxygen and other channels are optional; confirm the probe combination and conductivity cell constant.

Water quality sensor · pH sensor · Electrical conductivity sensor

Get a quote

Technical information

Specifications below are transcribed from the supplier page. Final configuration, calibration and suitability require confirmation before ordering.

Technical information · YF500-WQ
ModelYF500-WQ
Power supplyDC 10V~30V
Protection ratingIP68
Operating temperature-20℃ ~ 60℃
Power supply / Standard configuration24V
Standard configurationRS485 Modbus RTU
Optional configuration4-20mA / 0-5V / LoRaWAN / WiFi / BLE
Model / Configuration checklistYF500-WQ
Measurement parameters
Measurement parametersMeasurement rangeResolutionAccuracy
pH0~14.00PH0.01PH±0.15PH
Electrical conductivity sensor (K=1)1~2000μS/cm0.1μS/cm±1%FS
Electrical conductivity sensor (K=10)10~20000μS/cm1μS/cm±1%FS
Temperature-20~60℃0.1℃±0.5℃
Dissolved oxygen sensor (Optional configuration)0~20mg/L0.01mg/L±3%FS
The source labels 0.5W as operating current. This dimensionally inconsistent row is withheld. Optional channels and the probe combination require confirmation.

Supplier technical source: BEEIOT / YF500-WQ

Selection considerations

Downloads are not available until the technical documents and permission to distribute them are confirmed.

01

Measurement parameters

The YF500-WQ measures water pH, conductivity and temperature. Dissolved oxygen and other channels are optional; confirm the probe combination and conductivity cell constant.

02

Standard configuration / Optional configuration

RS485 Modbus and LoRaWAN are integration options to discuss, not confirmed features of every product. Check protocol, power supply and network compatibility for the selected model.

03

Calibration / Installation and maintenance

Pending confirmation. Specify the medium, target parameters, measurement range, required accuracy, installation conditions and controller interface. Suitability must be checked against an approved datasheet.

Built around your environment.

This page outlines project planning, not an installed customer case or a guaranteed outcome. Confirm product suitability, site conditions and the integration plan before procurement.

Describe freshwater or saltwater conditions, installation depth and cleaning access. Discuss dissolved oxygen, pH, conductivity and temperature needs. Confirm the probe maintenance and calibration plan.

Related measurement areas

Source reviewed · Configuration to confirmYF500-DO · Dissolved oxygen sensor for aquaculture

YF500-DO · Dissolved oxygen sensor for aquaculture

The YF500-DO uses optical fluorescence for dissolved oxygen measurement in aquaculture and other water-monitoring applications. Review water conditions, cleaning access and calibration before specifying the installation.

Technical information
Source reviewed · Configuration to confirmGDI51 · LoRaWAN gateway

GDI51 · LoRaWAN gateway

The GDI51 is an indoor LoRaWAN gateway based on the SX1302 chipset. Select the regional frequency version and confirm backhaul, power supply and network-server compatibility.

Technical information

Frequently asked questions

How do I choose a suitable sensor?

Specify the medium, target parameters, measurement range, required accuracy, installation conditions and controller interface. Suitability must be checked against an approved datasheet.

Are all communication options standard?

No. Interfaces, power supplies and accessories depend on the confirmed model. Request a written configuration identifying standard and optional items before ordering.

Can I submit an enquiry now?

You can prepare and download an enquiry draft. Mailbox, online submission and WhatsApp are pending configuration; delivery has not been tested.