Coco coir growing media
Technical specifications
| Detection Type | Range | Resolution | Accuracy |
|---|---|---|---|
| Temperature | -40~80℃ | 0.1℃ | ±0.5℃ |
| Substrate Moisture (VWC) | 0~100% VWC | 0.1% | ±3% (≤5% on non-soil substrate) |
| EC | 0~20 dS/m | 0.01 dS/m | ±5% (0–7) / ±10% (7–20) |
| Parameter | Specification |
|---|---|
| Operating Voltage | DC10V~30V (Standard 24V) |
| Warm-up Time | 2 min |
| Sampling Rate | Once per second (Default) |
| Output Method | RS485 Modbus RTU / 4-20mA / 0-5V / LoRaWAN / WiFi / BLE |
| Material | Flame-Retardant ABS Enclosure |
| Mounting | Pipe-Mount / Wall-Mount |
| Dimensions | 124×94×45mm (Main Unit) / 82×45×20mm (Probe; 90×55×75mm overall incl. pins & cable gland) |
| Operating Temperature | -20℃~60℃ |
| Operating Humidity | 0~100%RH (No Condensing) |
| Model | Communication | Description |
|---|---|---|
| YF500-CCS(R) | RS485 | Substrate Moisture / EC / Temperature Sensor |
| YF500-CCS(L) | LoRaWAN | Wireless Smart Agriculture Monitoring |
| YF500-CCS(W) | WiFi | Cloud Platform Integration |
| YF500-CCS(B) | Bluetooth | Local Configuration & Communication |
| YF500-CCS(20) | 4-20mA | Industrial Control Integration |
| YF500-CCS(V5) | 0-5V | PLC Analog Integration |
YF500-CCS coco coir substrate monitoring
The YF500-CCS measures substrate volumetric water content, electrical conductivity and temperature for coco coir growing media. These three measurements offer different views of the root zone: water content describes moisture, EC reflects the conductivity of the medium, and temperature provides context for the growing environment. The transmitter can be specified for a suitable wired or wireless monitoring system.
Monitoring coco coir in protected cultivation
Coir bags and slabs can vary in moisture across a greenhouse because of emitter condition, irrigation timing, drainage and crop uptake. A sensor provides information about the local root zone at its installation point. Select representative bags or beds and record their position so that changes can be compared over time. A single probe may not represent every plant, irrigation line or growing zone.
Review the readings alongside irrigation events, drainage observations and the crop’s development. Electrical conductivity can change as water and nutrients move through the medium. Interpret a substrate EC value in the context of the measurement method and growing medium; it should not automatically be treated as the same quantity as the EC of a collected irrigation or drain-water sample.
Ranges and configuration
The listed substrate moisture measurement range is 0–100% VWC. The listed EC range is 0–20,000 μS/cm with 1 μS/cm resolution and ±3% FS accuracy. The listed temperature measurement range is −40 to 80 °C with 0.1 °C resolution and ±0.5 °C accuracy. The main unit’s operating temperature is listed separately as −20 to 60 °C; consider both the probe and electronics when specifying a site.
The ordering table lists RS485, LoRaWAN, WiFi, Bluetooth, 4–20 mA and 0–5 V variants. Choose the model that matches the controller or data collection system. Confirm the supply, output, cable routing and any gateway requirements for the selected version.
Probe placement and installation
Choose a location that reflects the root zone and allows the probe to make consistent contact with the coir. Consider the position of emitters and drainage paths; placing a probe immediately beside an emitter can produce a different picture from the rest of the growing bag. Follow the installation instructions for insertion and avoid disturbing the sensing region after installation.
Plan enough access for inspection and removal. Keep records of the growing medium, probe location, irrigation zone and configuration. If changing substrate type or preparation, review the applicable calibration and compare readings with the intended measurement method.
Maintenance and ordering
Inspect the probe, cable and enclosure routinely. Clean according to the supplied instructions and investigate abrupt changes alongside irrigation and site conditions. For an enquiry, specify the medium, number of measurement points, required interface and controller. Explore the YF500-S soil sensor and greenhouse monitoring solution for related applications.
Selection and integration
Industry applications
- Commercial horticulture