Outdoor air quality monitoring
Technical specifications
| Parameter | Specification |
|---|---|
| Product Type | Compact Outdoor Air Quality Monitoring Terminal |
| Enclosure Material | Weather-resistant High Performance Plastic Housing |
| Protection Rating | IP55 |
| Outdoor Protection | UV Resistant, Anti-aging, Weatherproof Design |
| Installation Method | Wall Mount / Pole Mount |
| Dimensions | 310 × 233 × 142 mm |
| Parameter | Specification |
|---|---|
| DC Power Supply | DC10~30V |
| AC Power Supply | AC60~250V |
| Optional Power | PoE Power Supply |
| Solar Power Option | Optional Solar Power System Available |
| Interface | Option |
|---|---|
| Digital Output | RS485 Modbus |
| Analog Output | 4-20mA / 0-5V / 0-10V |
| Wireless Communication | WiFi / 4G / LoRaWAN / BLE |
| Parameter | Specification |
|---|---|
| Sampling Structure | Built-in Fan Assisted Sampling |
| Dust Protection | Multi-layer Dust Filter Structure |
| Sensor Configuration | Modular Combination According to Project Requirements |
| Alarm Function | Upper / Lower Threshold Alarm |
| Alarm Configuration | Local or Cloud Remote Configuration |
YF201 compact outdoor air quality monitor
The YF201 is a compact outdoor air quality monitoring terminal with a modular sensor configuration. It is intended for projects that need selected air and environmental measurements at a fixed location. Specify the required channels, power supply and communication method for the intended installation.
Select the monitoring location
Conditions at an outdoor measurement point depend on nearby sources, airflow, obstacles and weather. A monitor at a facility or campus describes the air reaching that location; it should not automatically be treated as representative of a wider region. Define the monitoring objective and review access, power and communications before selecting a mounting point.
Allow space for inspection and maintenance. Record the location, height, surrounding structures and selected sensor channels. If the installation or surroundings change, keep a record so that later data can be interpreted in context.
Configure the sensor channels
The YF201 uses a modular sensor combination according to project requirements. Identify the pollutants and environmental parameters that the project needs, then confirm the range and accuracy of each installed module. A configurable channel should not be assumed to be fitted in every unit.
The specifications describe fan-assisted sampling and a multilayer dust-filter structure. Review the sampling arrangement, site exposure and maintenance instructions for the actual configuration, including how filters and sensing elements are accessed.
Power, output and mounting
The listed options include DC 10–30 V, AC 60–250 V, optional PoE and an optional solar power system. Communication options include RS485 Modbus, analog and wireless versions. These are configuration choices: confirm the required supply and output with the order rather than assuming all options are included.
The product table lists wall or pole mounting, an IP55 enclosure and dimensions of 310 × 233 × 142 mm. Follow the supplied instructions for the chosen assembly and provide an installation appropriate to local weather and site conditions.
Commissioning and maintenance
Record the model, installed modules, measurement point and communications. During commissioning, check each channel and the data connection against the project requirements. Plan inspection, cleaning and calibration using the documentation for the actual installed sensors.
Share the monitoring site, target parameters, desired ranges, power source and interface when requesting a quotation. Explore the outdoor air and weather range and ambient air monitoring solution.
Selection and integration
Industry applications
- Environmental monitoring
- Industrial parks
- Transport infrastructure