SENSING THE WORLD. CONNECTING YOUR BUSINESS.www.odsenses.com
YF500-C2H4 Ethylene Gas Sensor
ODSENSE

YF500-C2H4 Ethylene Gas Sensor

The YF500-C2H4 ethylene gas sensor supports monitoring in fruit storage, ripening rooms and agricultural processing environments.

Fruit storage and ripening

Technical specifications

Technical Specification
ParameterSpecification
Ethylene (C₂H₄)0~100ppm
Resolution0.1ppm
Accuracy±5%FS
Response Time≤20s
Technical Specification
ParameterSpecification
Power SupplyDC 10~30V (24V Standard)
Protection RatingIP65 Waterproof & Dustproof
CommunicationRS485 Modbus / LoRaWAN / WiFi / BLE / 4G
Analog Output4-20mA / 0-5V
Housing MaterialFlame-retardant ABS
ApplicationFruit Ripening / Cold Storage / Agriculture
Model Selection / Ordering Information
ModelCommunicationApplication
YF500-C2H4(R)RS485Agricultural monitoring systems
YF500-C2H4(L)LoRaWANWireless farm monitoring
YF500-C2H4(W)WiFiLocal network monitoring
YF500-C2H4(4G)4GRemote monitoring applications
YF500-C2H4(B)BluetoothConfiguration and short distance communication
YF500-C2H4(20)4-20mAIndustrial control systems
YF500-C2H4(V5)0-5VPLC analog integration

YF500-C2H4 ethylene gas monitoring

The YF500-C2H4 is an ethylene gas sensor for monitoring applications in fruit storage, ripening and agricultural environments. It lists a 0–100 ppm measurement range, 0.1 ppm resolution and ±5% FS accuracy. Select the communication version and installation location to suit the monitoring system and the conditions at the site.

Ethylene and storage environments

Ethylene is associated with the ripening of many fruits. Concentrations can change with the stored product, room operation and ventilation. Monitoring can provide a record of the conditions at a measurement point, which can be reviewed alongside storage procedures and product observations.

Different locations in a room can experience different airflow and concentrations. The sensor should be placed where the reading is useful for the decision being made. Consider the location of ventilation, storage racks, access routes and possible ethylene sources when planning monitoring points.

Range and system selection

The listed measurement range is 0–100 ppm, with a response time of ≤20 seconds. Compare the expected concentrations with the range and accuracy requirements for the application. Resolution describes the smallest displayed increment; it is not the same as measurement accuracy.

The ordering table lists RS485, LoRaWAN, WiFi, 4G, Bluetooth, 4–20 mA and 0–5 V variants. These are configuration choices, not interfaces guaranteed on every device. Confirm the ordering code, power supply and receiving controller or gateway before installation.

Placement and commissioning

Choose an accessible position that represents the air to be monitored and does not obstruct the sensing element. Review the room layout, ventilation and normal work activities. Follow the product instructions and applicable site procedures for mounting, wiring and commissioning.

Record the installation point and configuration. At commissioning, check communication with the receiving system and verify readings using the appropriate procedure. When reviewing a trend, consider changes in room loading, operating schedule and ventilation as well as sensor condition.

Organising a monitoring programme

Label the measurement point and keep readings with the time, room and operating conditions. If several storage rooms are monitored, check that each sensor reports to the correct location in the receiving system. This record helps operators compare periods with similar loading and ventilation rather than relying on a single reading.

Maintenance and project information

Inspect the enclosure, sensing area and connections routinely. Plan cleaning and calibration according to the supplied product instructions and the actual environment. Investigate unexpected readings rather than assuming a single measurement describes the entire room.

For a quotation, provide the monitored gas, required range, number of rooms and measurement points, available power and preferred interface. Explore the smart agriculture sensor range for complementary measurements.

Selection and integration

Request product information

Discuss your project

Send your project enquiry to linda@odsenses.com. Required fields are marked with an asterisk.