SENSING THE WORLD. CONNECTING YOUR BUSINESS.www.odsenses.com
YF500-DP Differential Pressure Transmitter
ODSENSE

YF500-DP Differential Pressure Transmitter

The YF500-DP measures the pressure difference between two connection points for ventilation, filtration and related monitoring projects.

Differential pressure monitoring

Technical specifications

Range Selection Guide
Differential pressure rangeEquivalentAccuracyTypical use
0–0.1 kPa0–100 PaClass 0.5Cleanroom room-pressure cascade, negative-pressure ventilation
0–0.2 kPa0–200 PaClass 0.5Room pressure, airflow control
0–0.5 kPa0–500 PaClass 0.5Filter differential pressure, duct static pressure
0–1 kPa0–1000 PaClass 0.2 / 0.5Duct pressure, fan performance testing
0–2 kPa0–2000 PaClass 0.2 / 0.5Ventilation systems, furnace pressure
0–5 kPa0–5000 PaClass 0.2 / 0.5Industrial process, pipeline pressure
0–10 kPa0–10 kPaClass 0.2 / 0.5Gas pressure process control
Technical Specifications
MEASUREMENT
Measurement typeDifferential and micro differential pressure of gases; static pressure measurement also supported
Sensing principlePiezoresistive differential pressure chip with zero-point and span temperature compensation
Ranges7 ranges: 0–0.1 / 0–0.2 / 0–0.5 / 0–1 / 0–2 / 0–5 / 0–10 kPa
AccuracyClass 0.5 (standard); Class 0.2 optional for ranges of 1 kPa and above
Resolution0.1 Pa (smallest range)
Overload300% FS
Zero / span thermal drift±0.03% FS/°C
Compensated temperature0…+50°C
MECHANICAL
Main unitFlame-retardant ABS housing, 124 × 94 × 45 mm
ProbeStainless steel, 65 × 60 × 27.5 mm; 102 mm overall length including barbs
Pressure portsDual barbs Φ8 mm (H / L), 20.3 mm spacing, same side, horizontal outlet
Wetted materialsSilicon piezoresistive diaphragm, stainless steel barbs, FKM seals
Ingress protectionIP65
MountingWall mount, 4 × Φ4 mm holes with 44.5 mm vertical pitch; M10 cable entry with gland
ELECTRICAL & ENVIRONMENT
Supply voltageDC 12–30 V (24 V nominal)
Power consumption≤ 0.5 W
OutputRS485 Modbus RTU (standard); LoRaWAN / WiFi / 4G / Bluetooth optional
Operating conditions−20…+45°C, 15–95% RH (non-condensing)
Storage−30…+60°C, 0–99% RH (non-condensing)
Standard accessories3 m PU tubing (ID 8 mm), barb fittings and clamps, wall-through mounting bracket with wind shield, fixing screws
Installation, Wiring & Zero Check
PinSignalDescription
24VVCCPower input +24 V
GNDGNDGround
B485BModbus RS485 B
A485AModbus RS485 A

YF500-DP differential pressure transmitter

The YF500-DP measures differential and micro differential pressure of gases. It is intended for applications such as room pressure, filter monitoring and ventilation systems where the pressure difference between two points needs to be observed. The product specifications list seven measurement ranges, from 0–0.1 kPa to 0–10 kPa; select the range around the pressures expected in the application.

How differential pressure is used

A differential pressure reading compares the pressure at a high port with the pressure at a low port. In a ventilation installation, the two ports can be connected to points across a filter to observe the pressure drop. For room pressure monitoring, the measurement can compare a room with an adjacent reference area. The ports, tubing and measurement locations are part of the overall measurement system.

Pressure readings change with fan operation, damper position, airflow and site conditions. Define the purpose of the measurement before selecting the range. A range that is unnecessarily large can make small changes harder to interpret, while a range that is too small may not cover normal operating conditions. Review the complete measurement and overload specifications for the chosen version.

Range and accuracy selection

The listed ranges are 0–0.1, 0–0.2, 0–0.5, 0–1, 0–2, 0–5 and 0–10 kPa. The product specifications list class 0.5 as standard and class 0.2 as an option for ranges of 1 kPa and above. The smallest range lists 0.1 Pa resolution. Confirm the required range and accuracy class in the ordering information; resolution and accuracy describe different properties.

Installation and pressure connections

Identify the high and low pressure points and connect them to the corresponding ports according to the installation instructions. Plan tubing routes to prevent kinks, leaks or accidental disconnection. Avoid arrangements where condensate or contaminants can enter a port; review the suitability of the medium and the mounting location for the selected instrument.

Provide access for commissioning and maintenance. Record the connected pressure points and the expected direction of pressure difference so that operators can interpret the reading correctly. Check connections and zero adjustment using the procedure supplied for the instrument.

System integration and maintenance

Choose the output configuration to match the receiving controller or monitoring system, and check its supply voltage, wiring and communication settings. Record the installed range and settings in the site documentation. Periodic inspection of tubing, ports, mounting and electrical connections supports consistent monitoring.

For an enquiry, provide the gas, expected differential pressure, installation environment, required accuracy class and interface. Related products are available in the industrial sensor range; see also the industrial environment monitoring solution.

Selection and integration

Request product information

Discuss your project

Send your project enquiry to linda@odsenses.com. Required fields are marked with an asterisk.