YF500-CO Carbon Monoxide Gas Sensor
ODSENSE

YF500-CO Carbon Monoxide Gas Sensor

The YF500-CO measures carbon monoxide for industrial and facility monitoring projects.

Carbon monoxide monitoring

Technical specifications

Technical Specification
ParameterSpecification
Gas TypeCarbon Monoxide (CO)
Measurement Range0~1000ppm / 0~2000ppm
Resolution1ppm
Accuracy±5ppm or ±10%
Response Time≤30s
Warm-up Time≥5min
Service Life≥2 Years
Technical Specification
ParameterSpecification
Power SupplyDC10~30V (24V Standard)
Protection RatingIP65 Waterproof & Dustproof
Communication InterfaceRS485 Modbus RTU
Optional WirelessLoRaWAN / WiFi / Bluetooth / 4G
Analog Output4-20mA / 0-5V
Housing MaterialFlame-retardant ABS
InstallationWall Mount / Pipe Mount
Model Selection / Ordering Information
ModelCommunicationApplication
YF500-CO(R)RS485Industrial Monitoring System
YF500-CO(L)LoRaWANWireless Remote Monitoring
YF500-CO(W)WiFiCloud Platform Connection
YF500-CO(4G)4GRemote Area Monitoring
YF500-CO(20)4-20mAPLC Control System
YF500-CO(V5)0-5VAnalog Data Acquisition

YF500-CO carbon monoxide gas monitoring

The YF500-CO is a carbon monoxide sensor for environmental monitoring installations. The product specifications list 0–1,000 ppm and 0–2,000 ppm measurement ranges, with 1 ppm resolution. Choose the required range and communication configuration for the site, and check the ordering details before installation.

Plan carbon monoxide measurement

Carbon monoxide can be produced by incomplete combustion. Monitoring requirements depend on the equipment, location, ventilation and the people who may be present. Identify potential sources and the purpose of each measurement point as part of the site design. Conditions may differ between enclosed rooms, parking areas, workshops and other spaces.

Use the readings within a documented response plan. Select alarm thresholds, notification methods and actions according to the applicable local requirements and the installation’s design. A measurement device is one part of the overall safety system and must be specified for its intended use.

Measurement range and response

The product table lists two range options, 1 ppm resolution, a response time of ≤30 seconds and a warm-up time of ≥5 minutes.

Placement and commissioning

Choose monitoring positions in relation to likely sources, airflow, room layout, occupancy and access for maintenance. Avoid obstructions that prevent gas from reaching the sensing area. Follow the instructions and relevant site requirements for mounting height, installation and commissioning rather than assuming one position is suitable for every space.

Record the sensor location, measurement range and controller configuration. Allow for warm-up and use an appropriate check procedure when commissioning. Investigate unexpected readings in relation to operating equipment, ventilation and sensor condition.

Connecting the measurement to operations

Specify how each sensor will be identified in the receiving system and who will review its readings. Test the communication path and the site’s response procedure during commissioning, including the handling of an interrupted connection or loss of power. Record the test and the date of the next scheduled inspection.

Changes to combustion equipment, ventilation or the use of a room may affect the monitoring plan. Review the sensor locations and response arrangements whenever the site layout or operating conditions change.

Interface and maintenance

The product specifications list RS485 Modbus RTU for the wired interface, with LoRaWAN, WiFi, Bluetooth, 4G and analog options for different configurations. Select the model and signal that match the receiving controller or gateway. Confirm the power supply, cabling and network requirements with the order.

Arrange routine inspection and calibration according to the product instructions and the site’s applicable procedures. Protect the sensing area from physical damage and buildup. For a quotation, provide the number of monitoring points, required range, installation environment and communication interface. Explore the industrial sensor range and industrial environment monitoring solution.

Selection and integration

Request product information

Discuss your project