Technical Specification
ParameterSpecification
Product TypeIntegrated Air Quality Monitoring System
Sensor IntegrationSupports more than 10 types of gas and particulate sensors
Sensor CombinationCustomizable sensor configuration according to project requirements
Expansion ModulesWind Speed / Wind Direction / Noise / Other Environmental Modules
Technical Specification
CategoryAvailable Parameters
Gas DetectionO₂, CO, CO₂, H₂S, CH₄, Combustible Gas and other customized gases
Particle DetectionPM2.5 / PM10 / Particulate Matter
Environmental ParametersTemperature, Humidity, Wind Speed, Wind Direction, Noise (Optional)
Technical Specification
ParameterSpecification
Wired CommunicationRS485 Modbus RTU
Wireless CommunicationLoRaWAN Low Power Wireless
Cloud IntegrationSupports IoT cloud platform data upload and remote monitoring
Alarm FunctionUpper / Lower Threshold Alarm
Alarm ConfigurationLocal or Remote Cloud Configuration
Technical Specification
ParameterSpecification
Installation MethodWall Mount / Pipe Mount
DesignIntegrated Modular Structure
CustomizationHardware and sensor configuration customization available
Application EnvironmentIndoor and Outdoor Environmental Monitoring Projects

YF200 integrated air quality monitoring system

The YF200 is an integrated environmental monitoring system with a configurable combination of gas, particulate and environmental sensors. The selected measurement channels depend on the project requirements. Identify the parameters and installation conditions before choosing the system configuration.

Design the measurement plan

Outdoor monitoring projects may involve an industrial site, campus, facility boundary or another location where air conditions need to be observed over time. Start with the questions the monitoring system should answer, then select the parameters, number of measurement points and reporting needs for the site.

Gas and particulate measurements describe conditions at the sampling point. Nearby sources, structures, weather and access can influence what the instrument observes. Record the position and surrounding conditions so that the resulting data can be interpreted with the site context.

Select monitoring channels

The listed sensor options include gases, PM2.5 and PM10, and optional environmental measurements such as temperature, humidity, wind and noise. These are configurable channels; they should not be assumed to be present together on every system. Specify the required parameters and obtain the range, accuracy and configuration for each selected sensor.

When comparing systems, consider the measurement range and operating conditions of the individual channels as well as the system enclosure, sampling arrangement and maintenance access. Plan any additional weather measurements around the exposure of their own sensors.

Installation and connectivity

Choose a mounting location with suitable power, communications and safe access for inspection. The product information lists wall and pipe mounting. Review the complete installation with regard to airflow, obstructions, weather exposure and the equipment supplied for the chosen configuration.

RS485 Modbus RTU and LoRaWAN are listed communication methods. Confirm the selected output and network requirements with the order. Define how data will be received, stored and reviewed by the customer’s monitoring system; platform integration depends on the actual configuration and compatibility.

Commissioning and maintenance

Record the system configuration, installed sensor channels, location and communication settings. During commissioning, check that each configured parameter reaches the intended receiving system and is associated with the correct measurement point.

Plan inspection, cleaning and calibration according to the installed modules and the supplied documentation. Review unexpected changes alongside site conditions and maintenance records. For a quotation, provide the target pollutants, expected ranges, installation location, power and communication requirements.