Wind Sensor Siting: Height, Obstructions and Directional Exposure

Wind sensor siting determines what the measurement represents. A carefully calibrated sensor beside a building may accurately record a disturbed local flow while providing a poor estimate of open-field conditions. Define the intended use, select the required exposure and document the surroundings before comparing records or assigning a correction.
Start with the measurement objective
Decide whether the project needs representative meteorological wind, local equipment exposure or conditions at a specific crop or structure. The appropriate location and height depend on that purpose and any applicable project requirements. A convenient mounting point does not automatically satisfy them.
Campbell's weather-station siting guide shows how exposure considerations vary with the measurement. Confirm the current requirements applicable to the project rather than treating a generic recommendation as certification of an installation.
Map obstacles by direction
Record nearby buildings, trees, terrain changes and other potential obstructions. Their effect depends on wind direction as well as separation and height. Photograph the surroundings and identify sectors likely to experience disturbed flow.
Campbell's mesonet design discussion explains why surroundings matter when applying station observations more broadly. Do not assume that a sensor exposed in one direction is equally representative in every direction. Preserve the site description with the data, not only in a separate installation folder.

Consider the mast and mounting arrangement
The support structure, crossarm, cables and nearby instruments can also affect the local flow. Follow the sensor manufacturer's mounting instructions and the chosen exposure requirements. Ensure the intended measurement volume is clear and the structure remains stable under the site's expected conditions.
The anemometer type selection guide helps distinguish sensor technologies, but it does not remove siting constraints. Record the actual height and mount geometry. Installation at height must follow the site's approved access and structural procedures.
Establish the wind-direction reference
Identify the north reference expected by the project and the orientation procedure required by the instrument. Account for the difference between a physical installation reference and any software offset. Document the applied correction so that later servicing does not apply it again.
The Wind Monitor FAQ includes model-specific orientation and siting questions. Confirm whether the output describes the direction from which wind arrives and how the logger handles wraparound. Do not infer these settings from the appearance of a vane alone.
Match the recording and comparison basis
Check units, sample timing, averaging method and the definition of any gust channel. A short peak and a longer average are different quantities. Wind direction also needs appropriate circular or vector handling; an ordinary arithmetic mean can be misleading around the wraparound point.
Before comparing with another station, review height, exposure, distance and recording intervals. The anemometer accuracy guide separates reference checks from installed performance. Agreement during one period does not establish equivalence across all wind directions.
Revisit exposure after site changes
Vegetation growth, new buildings, moving equipment or a changed mast can alter the exposure after commissioning. Keep dated photographs and record maintenance that affects height or orientation. Review data discontinuities against those changes before attributing them to sensor drift.
The agricultural measurement planning guide helps connect placement with the decisions supported. If the site cannot meet the intended exposure, document the limitation and reassess the use of the data. Avoid inventing a fixed correction factor from a distant station's readings.
Frequently asked questions
Can calibration remove building-induced flow effects? Calibration characterizes the sensor response under specified conditions. It does not make a disturbed site equivalent to open terrain.
Is one mounting height correct for every application? No. Use the project's measurement objective and applicable requirements, then document the installed height.
Why do differences appear only for certain wind directions? Obstacles and support structures can affect some directions more strongly. Review directional exposure and matched records before changing calibration.