YF500 Residual Chlorine Water Quality Sensor
ODSENSE

YF500 Residual Chlorine Water Quality Sensor

The YF500 residual chlorine sensor supports continuous monitoring in suitable treatment and process-water applications.

Measurement principle

The YF500 uses constant-potential electrochemical measurement. It maintains the potential between the electrodes and measures the current generated by the residual chlorine reaction. Applications include water treatment, swimming pools, wastewater and industrial process water.

Residual chlorine monitoring

Residual chlorine measurement can support monitoring of treated water. Review the water matrix, measurement range and maintenance requirements for the selected installation.

Technical specifications

YF500-CL Residual Chlorine Sensor Specifications
General Parameters
ModelYF500-CL
Operating VoltageDC 10V–30V, standard 24V DC
Power Consumption0.5W at 24V DC
Waterproof RatingIP68
Pressure Resistance0.6 MPa
Standard CommunicationRS485, Modbus RTU
Optional CommunicationLoRaWAN / WiFi / 4G
Default Cable Length5 meters; customized cable lengths available
MountingPipe mount / Wall mount
Main Unit Dimensions124 × 94 × 45 mm
Operating Temperature0°C to 50°C
Operating Humidity0–99% RH, non-condensing
YF500-CL Residual Chlorine Sensor Specifications
Sensor Measurement Specifications
MeasurementRangeResolutionAccuracy
Residual Chlorine0–20 mg/L0.01 mg/L±3%FS
Model Selection
ModelCommunicationRecommended Use
YF500-CL(R)RS485 Modbus RTUPLC, controller and data logger integration
YF500-CL(L)LoRaWANLarge-area wireless monitoring
YF500-CL(W)WiFiLocal network and facility monitoring
YF500-CL(G)4GRemote sites without local network access

YF500 residual chlorine sensor

The YF500 monitors residual chlorine in water. Its listed measurement range is 0–20 mg/L, with 0.01 mg/L resolution and ±3% FS accuracy. The listed standard communication is RS485 Modbus RTU, with LoRaWAN, WiFi and 4G versions for other integration requirements.

Monitoring residual chlorine

Residual chlorine is commonly monitored where chlorine-based treatment is used. Readings should be interpreted alongside the treatment process, sampling location and water conditions. Decide whether the purpose is to observe a trend, review a process stage or support another monitoring task before selecting the measurement point.

Choose a representative location with access for cleaning and inspection. Flow, mixing and the time between dosing and measurement can influence the reading. A point immediately beside a dosing outlet may not represent water farther along the process. Document the monitoring location and use a consistent reference method when comparing results.

Range and configuration

The 0–20 mg/L range should be compared with the normal and expected maximum concentration for the site. Resolution is the increment reported by the instrument; the listed ±3% FS accuracy is a separate specification. Review both when determining whether the configuration meets the project requirements.

RS485 Modbus RTU is the standard interface; LoRaWAN, WiFi and 4G are optional communication configurations. Confirm the configuration, power supply, receiving controller and network equipment for the chosen version. The listed supply is DC 10–30 V, with 24 V standard.

Installation and routine care

Follow the supplied instructions for mounting, immersion and cable routing. Provide access to the sensing area and protect the cable from mechanical stress. The product specifications list a 5 m standard cable with customized lengths available; confirm the required length before ordering.

Water composition, deposits and biological growth can affect the sensing surface. Establish an inspection, cleaning and calibration routine appropriate to the actual water and the supplied probe instructions. Use appropriate reference procedures and keep a record of maintenance and calibration results.

Ordering information

Share the water type, expected chlorine range, monitoring location, mounting arrangement and preferred interface when requesting information. The water quality sensor range and water monitoring application provide related measurement options.

Planning the monitoring point

Before ordering, map the sampling point, expected concentration, water type and available power. Consider how water moves through the process and whether the selected point represents the condition you need to monitor. Allow enough space for safe access, probe removal and routine cleaning. If the site uses a sampling line, review its layout with the installation team and follow the supplied product instructions.

For integration, identify the receiving controller, cable route and required communication version. Record the selected configuration with the installation and calibration records. Compare readings using a consistent reference procedure and investigate changes alongside process conditions and maintenance history. These steps help the operating team interpret trends and maintain a useful record over time.

Selection and integration

Request product information

Discuss your project

Send your project enquiry to linda@odsenses.com. Required fields are marked with an asterisk.