SENSING THE WORLD. CONNECTING YOUR BUSINESS.www.odsenses.com
YF201 Compact Outdoor Air Quality Monitor
ODSENSE

YF201 Compact Outdoor Air Quality Monitor

The YF201 combines configurable outdoor air and environmental measurements in a compact IP55 enclosure. It supports wall or pole mounting and is available with wired and wireless communication options.

Outdoor air quality monitoring

Technical specifications

Technical Specification
ParameterSpecification
Product TypeCompact Outdoor Air Quality Monitoring Terminal
Enclosure MaterialWeather-resistant High Performance Plastic Housing
Protection RatingIP55
Outdoor ProtectionUV Resistant, Anti-aging, Weatherproof Design
Installation MethodWall Mount / Pole Mount
Dimensions310 × 233 × 142 mm
Technical Specification
ParameterSpecification
DC Power SupplyDC10~30V
AC Power SupplyAC60~250V
Optional PowerPoE Power Supply
Solar Power OptionOptional Solar Power System Available
Technical Specification
InterfaceOption
Digital OutputRS485 Modbus
Analog Output4-20mA / 0-5V / 0-10V
Wireless CommunicationWiFi / 4G / LoRaWAN / BLE
Technical Specification
ParameterSpecification
Sampling StructureBuilt-in Fan Assisted Sampling
Dust ProtectionMulti-layer Dust Filter Structure
Sensor ConfigurationModular Combination According to Project Requirements
Alarm FunctionUpper / Lower Threshold Alarm
Alarm ConfigurationLocal or Cloud Remote Configuration

YF201 compact outdoor air quality monitor

The YF201 is a compact outdoor air quality monitoring terminal with a modular sensor configuration. It is intended for projects that need selected air and environmental measurements at a fixed location. Specify the required channels, power supply and communication method for the intended installation.

Select the monitoring location

Conditions at an outdoor measurement point depend on nearby sources, airflow, obstacles and weather. A monitor at a facility or campus describes the air reaching that location; it should not automatically be treated as representative of a wider region. Define the monitoring objective and review access, power and communications before selecting a mounting point.

Allow space for inspection and maintenance. Record the location, height, surrounding structures and selected sensor channels. If the installation or surroundings change, keep a record so that later data can be interpreted in context.

Configure the sensor channels

The YF201 uses a modular sensor combination according to project requirements. Identify the pollutants and environmental parameters that the project needs, then confirm the range and accuracy of each installed module. A configurable channel should not be assumed to be fitted in every unit.

The specifications describe fan-assisted sampling and a multilayer dust-filter structure. Review the sampling arrangement, site exposure and maintenance instructions for the actual configuration, including how filters and sensing elements are accessed.

Power, output and mounting

The listed options include DC 10–30 V, AC 60–250 V, optional PoE and an optional solar power system. Communication options include RS485 Modbus, analog and wireless versions. These are configuration choices: confirm the required supply and output with the order rather than assuming all options are included.

The product table lists wall or pole mounting, an IP55 enclosure and dimensions of 310 × 233 × 142 mm. Follow the supplied instructions for the chosen assembly and provide an installation appropriate to local weather and site conditions.

Commissioning and maintenance

Record the model, installed modules, measurement point and communications. During commissioning, check each channel and the data connection against the project requirements. Plan inspection, cleaning and calibration using the documentation for the actual installed sensors.

Share the monitoring site, target parameters, desired ranges, power source and interface when requesting a quotation. Explore the outdoor air and weather range and ambient air monitoring solution.

Selection and integration

Request product information

Discuss your project

Send your project enquiry to linda@odsenses.com. Required fields are marked with an asterisk.