SENSING THE WORLD. CONNECTING YOUR BUSINESS.www.odsenses.com
YF500-EC Water Quality Conductivity Sensor
ODSENSE

YF500-EC Water Quality Conductivity Sensor

The YF500-EC measures electrical conductivity and temperature in suitable water and nutrient-solution applications.

Electrical conductivity monitoring

Technical specifications

Model Options
ModelDescription
YF500-EC(R)EC Water Quality Sensor with RS485 Modbus RTU
YF500-EC(L)EC Water Quality Sensor with LoRaWAN
YF500-EC(W)EC Water Quality Sensor with WiFi
YF500-EC(G)EC Water Quality Sensor with 4G

YF500-EC online conductivity monitoring

The YF500-EC measures water conductivity and temperature for applications such as aquaculture, hydroponics, treatment and industrial water monitoring. The product specifications list two cell-constant configurations: K=1 for 1–2,000 μS/cm and K=10 for 10–20,000 μS/cm. Select the appropriate version for the expected water conductivity rather than treating the ranges as interchangeable.

What conductivity tells you

Electrical conductivity describes a solution’s ability to carry electrical current and is influenced by dissolved ions. It is useful for observing changes in water or nutrient solutions, but it does not identify each dissolved substance. Interpret an EC trend with the water source, process conditions, temperature and any other measurements needed for the application.

Temperature affects conductivity. The sensor lists temperature measurement and automatic compensation; when comparing readings, use the same reporting convention and reference conditions. Salinity or total dissolved solids values derived from conductivity are conversions and depend on the assumptions used for the water being measured.

Choose the cell constant and measurement point

The listed K=1 range has a resolution of 0.1 μS/cm, while K=10 has a resolution of 1 μS/cm. Both list conductivity accuracy of ±1% of full scale. Consider the normal and expected extremes of the process, not just the value measured on one day. Ask for the selected cell constant and range to be stated on the order.

Position the probe in representative, well-mixed water with access for inspection. Avoid stagnant pockets, trapped bubbles and locations where the sensing area can be blocked. In nutrient solutions, consider the mixing and dosing cycle; in treatment systems, choose a point that answers the process question being investigated.

Integration options

RS485 Modbus RTU is the listed standard output. The ordering table lists LoRaWAN, WiFi and 4G versions for other communication arrangements. Confirm the power supply, model code, controller protocol, cable route and required network equipment before installation. Wireless versions depend on the network available at the site.

Cleaning, calibration and records

Deposits or biological growth can affect the sensing surface. Define a cleaning and inspection interval for the actual water and follow the supplied probe instructions. Use suitable conductivity standards when calibrating or checking the system, and keep records of the standard, temperature, date and results.

If measurements drift unexpectedly, check the probe, cable, temperature and sample conditions before attributing the change to the water alone. The listed main unit operating environment is 0–50 °C; the sensor temperature measurement range is separately listed as −20–60 °C. Review both limits for the installation.

Share the expected EC range, water type, installation location and desired interface when requesting product information. Related options include the water quality sensor range, the YF500-WQ multiparameter sensor and the aquaculture water quality solution.

Selection and integration

Request product information

Discuss your project

Send your project enquiry to linda@odsenses.com. Required fields are marked with an asterisk.