Air velocity and temperature monitoring
Technical specifications
| Application | Typical velocity / temp. | Notes |
|---|---|---|
| Comfort supply air | 2–6 m/s · 14–26 °C | Normal supply-duct velocity |
| Kitchen exhaust | 8–15 m/s · 40–80 °C | Codes usually require ≥ 8 m/s to avoid grease build-up |
| Cleanroom supply | 1–3 m/s · 20–24 °C | Low velocity — choose the 5 or 10 m/s range |
| Tunnel / mine | 1–10 m/s · 5–35 °C | Long-run ventilation; 0.1 m/s start-up covers low flow |
| MEASUREMENT | |
|---|---|
| Velocity range | 0–30 m/s (full scale 5 / 10 / 20 / 30 m/s built to order) |
| Velocity accuracy | ±3 %FS (±0.9 m/s on the 30 m/s range) |
| Start-up velocity | 0.1 m/s |
| Velocity response | ≤ 3 s |
| Air temperature range | −30 to 60 °C, accuracy ±0.5 °C (@25 °C), response ≤ 30 s |
| Resolution | 0.1 m/s / 0.1 °C |
| Measured medium | Air / nitrogen / grease-laden exhaust |
| Calibration | Wind-tunnel calibrated point by point, paired with its enclosure; calibration record included |
| ELECTRICAL | |
| Operating voltage | DC 12–24 V (24 V standard) |
| Operating current | ≤ 100 mA (overall peak) |
| Sampling rate | 1 s (default), configurable |
| Output | RS485 by default; 4–20 mA / 0–5 V (0–10 V) / LoRaWAN / Wi-Fi / BLE / 4G optional |
| ENVIRONMENT & MECHANICAL | |
| Operating temperature | −30 to 80 °C, 0–95 %RH (non-condensing) |
| Ingress protection | IP67 |
| Probe | 304 stainless steel, Ø19 × 236 mm, Ø3 pressure ports 20 mm from tip |
| Enclosure | 150 × 90 × 50 mm, independent wiring chamber |
| Mounting | Duct insertion with sliding L-bracket / U-clamp; probe cable 2 m (5 m / 10 m optional) |
YF500-WS air velocity and temperature transmitter
The YF500-WS combines air velocity and temperature measurement for ventilation monitoring. Its specifications list a 0–30 m/s velocity range, with 5, 10, 20 or 30 m/s full-scale versions built to order, and an air temperature measurement range of −30 to 60 °C. Specify the intended range and output when selecting the transmitter.
Understanding duct measurements
Air velocity varies across a duct and can be affected by bends, transitions, fans and dampers. A probe measures conditions at its position; it does not automatically measure the average velocity or total airflow for the entire duct. Define the purpose of the reading and consider the duct layout, access and airflow profile when choosing the measurement point.
Temperature provides additional context for the air stream. Compare the expected operating conditions with the stated measurement and environmental limits for both the probe and electronics. A measurement range should not be treated as a guarantee that every part of the assembly can operate at every point in that range.
Range and accuracy
The listed velocity accuracy is ±3% FS, with 0.1 m/s resolution and a 0.1 m/s starting velocity. A smaller full-scale range may provide a different absolute full-scale accuracy value from a larger range. Review the expected normal flow and peak conditions before selecting among the listed options.
The temperature channel lists 0.1 °C resolution and ±0.5 °C accuracy at 25 °C. Accuracy and resolution describe different properties; consider the stated conditions when comparing instruments.
Mounting and integration
The product specifications describe duct insertion with a sliding bracket or clamp. Select an accessible installation point and follow the supplied instructions for insertion depth, orientation and securing the probe. Route the cable to prevent damage and allow the probe to be removed for inspection.
RS485 is listed as the default output, with analog and wireless options for other configurations. Confirm the selected output, supply voltage and receiving system before ordering. The listed operating supply is DC 12–24 V; verify compatibility with the available power.
Inspection and commissioning
Keep the sensing openings clear and inspect the probe and mounting routinely. Dust, grease or deposits in the air stream may require a maintenance plan suited to the application. Follow the manufacturer’s supplied instructions for cleaning and verification.
Record the model, selected range, probe position and controller settings. Investigate unexpected readings in relation to system operating conditions and the probe’s condition. For related options, explore the industrial sensor range and industrial environment solution.
Selection and integration
Industry applications
- HVAC engineering
- Commercial buildings
- Manufacturing