The YF500-W monitors water leakage at selected locations and connects leak detection to a facility monitoring or alarm system.
Water leak monitoring
Leak monitoring can be planned around equipment rooms, water lines and locations where water could collect. Consider cable routing, placement and the response system connected to the selected version.
Technical specifications
| Parameter | Specification |
|---|---|
| Detection Item | Water Leakage |
| Detection Method | AC Detection Technology |
| Sampling Rate | 1 Second |
| Warm-up Time | 2 Minutes |
| Parameter | Specification |
|---|---|
| Operating Voltage | DC10~30V |
| Communication | RS485 Modbus RTU |
| Optional Output | 4-20mA / 0-5V / LoRaWAN / WiFi / BLE / 4G |
| Relay Output | One Relay Output (COM / NO / NC Dry Contact) |
| Relay Function | Water Leakage Alarm Linkage Control |
| Parameter | Specification |
|---|---|
| Protection Rating | IP67 |
| Housing Material | Flame-retardant ABS |
| Installation | Wall Mount / Pipe Mount |
| Operating Temperature | -20℃~60℃ |
| Operating Humidity | 0~99%RH Non-condensing |
| Model | Communication | Application |
|---|---|---|
| YF500-W(R) | RS485 | Industrial Water Leak Monitoring |
| YF500-W(L) | LoRaWAN | Wireless Remote Monitoring |
| YF500-W(W) | WiFi | IoT Cloud Platform |
| YF500-W(B) | Bluetooth | Local Configuration |
| YF500-W(20) | 4-20mA | Industrial Controller Integration |
| YF500-W(V5) | 0-5V | Analog System Integration |
Water leak detection for equipment and facilities
The YF500-W water leak detection sensor supports monitoring at locations where an unexpected water release could affect equipment or operations. It uses AC detection technology and provides a relay contact for alarm linkage. A detection point can be placed where water is expected to collect, while the transmitter connects the point to the selected monitoring or control system.
Applications include plant rooms, service corridors, water-handling equipment and areas beneath pipework. The sensor helps a facility team identify a leak condition at a monitored location; the actual coverage depends on the sensing arrangement, floor drainage and placement. Plan multiple detection points where a single location cannot cover the area of concern.
Plan the detection point
Start with the likely sources and routes of water. Review valves, joints, equipment connections, floor slopes and drains, then choose accessible points where leaking water is likely to reach the sensing element. Protect cables from mechanical damage and keep connections suitable for the surrounding conditions. Verify that the sensing arrangement is appropriate for the surface and installation instructions.
The specifications list a one-second sampling interval and a two-minute warm-up time. The enclosure is rated IP67 and uses flame-retardant ABS. The stated operating environment is −20 to 60 °C and 0–99% RH, non-condensing. Select mounting and cable entry arrangements that maintain the protection required at the site.
Connect the monitoring system
The YF500-W lists RS485 Modbus RTU communication and a relay with COM, normally open and normally closed dry contacts. Depending on the ordered version, analog and wireless options are also listed. Choose the interface that matches the receiving controller and confirm its electrical requirements, wiring and communication settings before installation. Options represent different configurations and should not be assumed to be included together.
Use the relay in a properly designed alarm circuit if local indication or a control-system input is required. Define who receives an alarm and how a leak will be inspected and resolved. Test the complete chain from the sensing point to the receiving system during commissioning; a contact output alone does not establish that an alarm will be acted upon.
Commissioning and routine checks
Record the device location, supply, connection, alarm destination and any settings. After installation, test the sensor using the method provided in its instructions and verify the receiving system reports the expected state. Check the sensing area and cable route periodically for contamination, obstruction or damage. Repeat the functional test after maintenance or a layout change.
For a quotation, provide the number of monitored areas, expected cable routes, available DC supply and preferred output. Describe whether the project needs a local relay contact, an industrial controller connection or a wireless version so the required configuration can be identified.
Selection and integration
Industry applications
- Facility management
- Commercial refrigeration


Selection and installation considerations
Identify the water paths, floor layout and locations that need coverage before choosing the sensing arrangement. Confirm the ordered detection cable or probe, power and signal interface, then test a representative leak condition during commissioning. Plan inspection and reset access after a detected event.