YF500-W Water Leak Detection Sensor
ODSENSE

YF500-W Water Leak Detection Sensor

The YF500-W connects water leak detection at selected locations to facility monitoring systems.

The YF500-W monitors water leakage at selected locations and connects leak detection to a facility monitoring or alarm system.

Water leak monitoring

Leak monitoring can be planned around equipment rooms, water lines and locations where water could collect. Consider cable routing, placement and the response system connected to the selected version.

Technical specifications

Technical Specification
ParameterSpecification
Detection ItemWater Leakage
Detection MethodAC Detection Technology
Sampling Rate1 Second
Warm-up Time2 Minutes
Technical Specification
ParameterSpecification
Operating VoltageDC10~30V
CommunicationRS485 Modbus RTU
Optional Output4-20mA / 0-5V / LoRaWAN / WiFi / BLE / 4G
Relay OutputOne Relay Output (COM / NO / NC Dry Contact)
Relay FunctionWater Leakage Alarm Linkage Control
Technical Specification
ParameterSpecification
Protection RatingIP67
Housing MaterialFlame-retardant ABS
InstallationWall Mount / Pipe Mount
Operating Temperature-20℃~60℃
Operating Humidity0~99%RH Non-condensing
Model Selection / Ordering Information
ModelCommunicationApplication
YF500-W(R)RS485Industrial Water Leak Monitoring
YF500-W(L)LoRaWANWireless Remote Monitoring
YF500-W(W)WiFiIoT Cloud Platform
YF500-W(B)BluetoothLocal Configuration
YF500-W(20)4-20mAIndustrial Controller Integration
YF500-W(V5)0-5VAnalog System Integration

Water leak detection for equipment and facilities

The YF500-W water leak detection sensor supports monitoring at locations where an unexpected water release could affect equipment or operations. It uses AC detection technology and provides a relay contact for alarm linkage. A detection point can be placed where water is expected to collect, while the transmitter connects the point to the selected monitoring or control system.

Applications include plant rooms, service corridors, water-handling equipment and areas beneath pipework. The sensor helps a facility team identify a leak condition at a monitored location; the actual coverage depends on the sensing arrangement, floor drainage and placement. Plan multiple detection points where a single location cannot cover the area of concern.

Plan the detection point

Start with the likely sources and routes of water. Review valves, joints, equipment connections, floor slopes and drains, then choose accessible points where leaking water is likely to reach the sensing element. Protect cables from mechanical damage and keep connections suitable for the surrounding conditions. Verify that the sensing arrangement is appropriate for the surface and installation instructions.

The specifications list a one-second sampling interval and a two-minute warm-up time. The enclosure is rated IP67 and uses flame-retardant ABS. The stated operating environment is −20 to 60 °C and 0–99% RH, non-condensing. Select mounting and cable entry arrangements that maintain the protection required at the site.

Connect the monitoring system

The YF500-W lists RS485 Modbus RTU communication and a relay with COM, normally open and normally closed dry contacts. Depending on the ordered version, analog and wireless options are also listed. Choose the interface that matches the receiving controller and confirm its electrical requirements, wiring and communication settings before installation. Options represent different configurations and should not be assumed to be included together.

Use the relay in a properly designed alarm circuit if local indication or a control-system input is required. Define who receives an alarm and how a leak will be inspected and resolved. Test the complete chain from the sensing point to the receiving system during commissioning; a contact output alone does not establish that an alarm will be acted upon.

Commissioning and routine checks

Record the device location, supply, connection, alarm destination and any settings. After installation, test the sensor using the method provided in its instructions and verify the receiving system reports the expected state. Check the sensing area and cable route periodically for contamination, obstruction or damage. Repeat the functional test after maintenance or a layout change.

For a quotation, provide the number of monitored areas, expected cable routes, available DC supply and preferred output. Describe whether the project needs a local relay contact, an industrial controller connection or a wireless version so the required configuration can be identified.

Selection and integration

Request product information

Selection and installation considerations

Identify the water paths, floor layout and locations that need coverage before choosing the sensing arrangement. Confirm the ordered detection cable or probe, power and signal interface, then test a representative leak condition during commissioning. Plan inspection and reset access after a detected event.