| Parameter | Specification |
|---|---|
| Ethylene (C₂H₄) | 0~100ppm |
| Resolution | 0.1ppm |
| Accuracy | ±5%FS |
| Response Time | ≤20s |
| Parameter | Specification |
|---|---|
| Power Supply | DC 10~30V (24V Standard) |
| Protection Rating | IP65 Waterproof & Dustproof |
| Communication | RS485 Modbus / LoRaWAN / WiFi / BLE / 4G |
| Analog Output | 4-20mA / 0-5V |
| Housing Material | Flame-retardant ABS |
| Application | Fruit Ripening / Cold Storage / Agriculture |
| Model | Communication | Application |
|---|---|---|
| YF500-C2H4(R) | RS485 | Agricultural monitoring systems |
| YF500-C2H4(L) | LoRaWAN | Wireless farm monitoring |
| YF500-C2H4(W) | WiFi | Local network monitoring |
| YF500-C2H4(4G) | 4G | Remote monitoring applications |
| YF500-C2H4(B) | Bluetooth | Configuration and short distance communication |
| YF500-C2H4(20) | 4-20mA | Industrial control systems |
| YF500-C2H4(V5) | 0-5V | PLC analog integration |
YF500-C2H4 ethylene gas monitoring
The YF500-C2H4 is an ethylene gas sensor for monitoring applications in fruit storage, ripening and agricultural environments. It lists a 0–100 ppm measurement range, 0.1 ppm resolution and ±5% FS accuracy. Select the communication version and installation location to suit the monitoring system and the conditions at the site.
Ethylene and storage environments
Ethylene is associated with the ripening of many fruits. Concentrations can change with the stored product, room operation and ventilation. Monitoring can provide a record of the conditions at a measurement point, which can be reviewed alongside storage procedures and product observations.
Different locations in a room can experience different airflow and concentrations. The sensor should be placed where the reading is useful for the decision being made. Consider the location of ventilation, storage racks, access routes and possible ethylene sources when planning monitoring points.
Range and system selection
The listed measurement range is 0–100 ppm, with a response time of ≤20 seconds. Compare the expected concentrations with the range and accuracy requirements for the application. Resolution describes the smallest displayed increment; it is not the same as measurement accuracy.
The ordering table lists RS485, LoRaWAN, WiFi, 4G, Bluetooth, 4–20 mA and 0–5 V variants. These are configuration choices, not interfaces guaranteed on every device. Confirm the ordering code, power supply and receiving controller or gateway before installation.
Placement and commissioning
Choose an accessible position that represents the air to be monitored and does not obstruct the sensing element. Review the room layout, ventilation and normal work activities. Follow the product instructions and applicable site procedures for mounting, wiring and commissioning.
Record the installation point and configuration. At commissioning, check communication with the receiving system and verify readings using the appropriate procedure. When reviewing a trend, consider changes in room loading, operating schedule and ventilation as well as sensor condition.
Organising a monitoring programme
Label the measurement point and keep readings with the time, room and operating conditions. If several storage rooms are monitored, check that each sensor reports to the correct location in the receiving system. This record helps operators compare periods with similar loading and ventilation rather than relying on a single reading.
Maintenance and project information
Inspect the enclosure, sensing area and connections routinely. Plan cleaning and calibration according to the supplied product instructions and the actual environment. Investigate unexpected readings rather than assuming a single measurement describes the entire room.
For a quotation, provide the monitored gas, required range, number of rooms and measurement points, available power and preferred interface. Explore the smart agriculture sensor range for complementary measurements.
Selection and integration
Industry applications
- Postharvest fruit handling
- Cold-chain logistics